6-2-3-6-rele-kontrolnojj-lampy-zaryada-akkumulyatornojj-batarei.html
6.2.3.6. The relay of a control lamp of a charge of the storage batteryThe relay of type РС-702 is intended for inclusion of a control lamp in a combination of devices when pressure of the generator is not enough for a charge of the storage battery. The relay is established in a motor compartment on the top part of a mudguard of the right wheel. In the switched off condition relay contacts are closed.
The relay winding (at the working generator) is under the straightened phase pressure of the generator and relay contacts are opened. If pressure between a clip «30» generators and "weight" equally 13,8–14,5 In, makes the straightened phase pressure 5–7 Century
Data for check
Pressure of disconnection
Contacts *, In |
5,3 ± 0,4
|
Pressure of short circuit
Contacts *, In |
0,2 – 1,5
|
Resistance of a winding
The relay at 20 ° With, the Ohm |
29 + 2
|