6-2-5-vozmozhnye-neispravnosti-generatora-ikh-prichiny-i-metody-ustraneniya.html
|
THE REASON
|
ELIMINATION METHOD
|
|
The control lamp burns or periodically lights up
At car movement
|
| Проскальзывание a belt of a drive of the generator | Adjust a belt tension |
| Breakage in connection between the tip «85» relays of a control lamp of a charge and the centre of a star of the generator | Check up and restore connection |
| The relay of a control lamp of a charge is disadjusted or damaged |
Check up the relay, adjust it or replace
|
| Breakage in a feed circuit of a winding of excitation |
Restore connection
|
| The pressure regulator is disadjusted or damaged |
Smooth out contacts, adjust or replace a regulator
|
| Deterioration or lag of brushes of the generator; oxidation of contact rings |
Replace щеткодержатель with brushes; wipe rings a rag moistened in gasoline
|
| Breakage or short circuit on weight of conclusions of a winding of excitation of the generator |
Attach winding conclusions to contact rings or replace a rotor
|
| Short circuit of one or several "positive" gates of the generator |
Replace выпрямительный the generator block
|
| Breakage in one or several gates of the generator |
Replace выпрямительный the generator block
|
| Breakage in connection between tips «86» and «87» relays of a control lamp of a charge |
Restore connection
|
| Breakage or межвитковое short circuit in a winding статора | Replace статор the generator |
|
The control lamp does not light up at ignition inclusion
|
| Has fused an incandescent filament | Replace a lamp |
| The relay of a control lamp of a charge is disadjusted or damaged | Smooth out contacts, adjust or replace the relay |
| Breakage in connection between the tip «87» relays of a control lamp of a charge and tip "I" of the block of safety locks |
Restore connection
|
| Short circuit of one or several "negative" gates of the generator | Replace выпрямительный the generator block |
| Winding short circuit статора on weight | Replace статор |
|
The generator works, the storage battery is charged poorly
|
| Weak tension of a belt; проскальзывание at the big frequency of rotation and at generator work under loading | Adjust a belt tension |
| Fastening of tips of wires on the generator and the storage battery is weakened; conclusions of the storage battery are oxidised; wires are damaged |
Clear conclusions of the battery of oxides, tighten clips, replace the damaged wires
|
| The storage battery is faulty |
Replace the battery
|
| The pressure regulator is disadjusted or damaged | Smooth out contacts, adjust or replace a pressure regulator |
|
The storage battery is recharged
|
| Bad contact between weight and the case of a regulator of pressure | Restore contact |
| The pressure regulator is disadjusted or damaged | Adjust or replace a pressure regulator |
| The storage battery is faulty | Replace the battery |
|
Raised шумность the generator
|
| The nut of a pulley of the generator is weakened | Tighten a nut |
| Погнуты fan blades |
Отрихтуйте the fan or replace
|
| Generator bearings are damaged |
Replace bearings
|
| Mezhvitkovoe short circuit or short circuit on weight of a winding статора (howl the generator) |
Replace статор
|
| Short circuit in one of generator gates | Replace выпрямительный the block |
| Scratch of brushes | Wipe brushes and contact rings the cotton napkin moistened in gasoline |