11-6-5-proverka-datchikov-kontrolnykh-priborov.html
11.6.5. Check of gauges of control devicesGauge BM-150 type. It is established in a fuel tank and fastens to it screws.
The gauge has the variable resistor from нихромовой a wire.
Mobile contact of the resistor copes the lever with a float. On the short end of this lever there is also the mobile contact including a control lamp of a reserve of fuel if in a tank there were 4–6,5 l of gasoline.
At an empty tank resistance of the gauge should be 315–345 Ohm, with a tank filled half – 108–128 Ohm, and at a full tank – it is less or equally 7 Ohm.
|